TM 9-2320-365-20-2
2-1349
CONTINUITY TEST
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
110/208 vac ground.
(3) Connect negative (-) probe of multimeter to
terminal board TB3 wire 3085Y and note
reading on multimeter.
(4) If continuity is not present, repair or replace
wire 3085Y (para 2-40).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
110/208 vac IN connector pin A.
(3) Connect negative (-) probe of multimeter to
circuit breaker CB1 left input terminal and note
reading on multimeter.
(4) If continuity is not present, repair or replace
wire 500 (para 2-40).
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
110/208 vac IN connector pin B.
(3) Connect negative (-) probe of multimeter to
circuit breaker CB1 middle input terminal and note
reading on multimeter.
(4) If continuity is not present, repair or replace
wire 501 (para 2-40).