TM 9-2320-365-20-2
2-1344
e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT)
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
Is continuity present on
wire 3085N from 110/208
vac IN connector pin G1
to ground?
If continuity is not present,
wire 3085N is faulty.
12/24 vdc circuits OK.
Circuit breaker CB1 OK.
Wire 1499N OK.
POSSIBLE PROBLEMS
Faulty wire 3085N.
Faulty wire 3085P.
Faulty wire 3085Q.
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
5.
6.
12/24 vdc circuits OK.
Circuit breaker CB1 OK.
Wire 1499N OK.
Wire 3085N OK.
POSSIBLE PROBLEMS
Faulty wire 3085P.
Faulty wire 3085Q.
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
Is continuity present on
wire 3085P from 110/208
vac IN connector pin G2
to ground?
If continuity is not present,
wire 3085P is faulty.
Repair or replace
wire 3085N (para 2-40).
Repair or replace
wire 3085P (para 2-40).