TM 9-2320-365-20-2
2-1346
e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT)
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
Is continuity present on
wire 3085Q from 110/208
vac IN connector pin G3
to ground?
If continuity is not present,
wire 3085Q is faulty.
7.
8.
12/24 vdc circuits OK.
Circuit breaker CB1 OK.
Wire 1499N OK.
Wire 3085N OK.
Wire 3085P OK.
POSSIBLE PROBLEMS
Faulty wire 3085Q.
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
If continuity is not present,
wire 3085R is faulty.
12/24 vdc circuits OK.
Circuit breaker CB1 OK.
Wire 1499N OK.
Wire 3085N OK.
Wire 3085P OK.
Wire 3085Q OK.
POSSIBLE PROBLEMS
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
Is continuity present on
wire 3085R from 110/208
vac IN connector pin G4
to ground?
Repair or replace
wire 3085Q (para 2-40).
Repair or replace
wire 3085R (para 2-40).