TM 9-2320-365-20-2
2-1342
e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT)
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
If continuity is not present,
wire 1499N is faulty.
Is continuity present on
wire 1499N from 110/208
vac IN connector pin N to
terminal board TB4?
12/24 vdc circuits OK.
Circuit breaker CB1 OK.
POSSIBLE PROBLEMS
Faulty wire 1499N.
Faulty wire 3085N.
Faulty wire 3085P.
Faulty wire 3085Q.
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
4.
Repair or replace
wire 1499N (para 2-40).