RESISTANCE TEST
TM 9-2320-365-20-2
Change 1 2-1409
Table 2-23. Transmission Solenoid F and G
Resistance Test Points
Sub
Code
Affected
Solenoid
Connector
P119 High
Connector
P119 Low
21
26
F
N
F
K
H
A
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector P119. Refer to Table 2-23.
Transmission Solenoid F and G Resistance
Test Points.
(3) Connect negative (-) probe of multimeter to
connector P119 and note reading on
multimeter. Refer to Table 2-23.
Transmission Solenoid F and G Resistance
Test Points.
(4) Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) If good resistance is not noted in step 3, or
continuity is present in step 4 or step 5,
replace WTEC II cab transmission harness
(para 7-86).
(7) If good resistance is noted in step 3, and
continuity is not present in step 4 or step
5, replace WTEC II TEPSS (para 8-2).
(8) Connect connector P119 to connector J119.
(9) Position front grille on cab with washer and
screw.
(10) Position two washers and screws in front
grille.
(11) Tighten screw to 48-60 lb-in. (5-7 N·m).
(12) Tighten two screws to 24 lb-in. (3 N·m).
(13) Connect connectors J114 and J115 to
WTEC II TEPSS.
(14) Install instrument panel assembly (para 7-15).
(15) Clear diagnostic codes (para 8-4).