TM 9-2320-365-20-2
2-1116
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
5.
POSSIBLE PROBLEMS
NO
YES
If continuity is not present,
wire 706B is faulty. If
continuity is present, relay
K41 is faulty.
Is continuity present on
wire 706B from INTERIOR
LIGHTS switch S32 to
fluorescent light DS80
wire 706B splice?
Repair or replace wire
706B (para 2-40).
110 vac outlets OK.
Circuit breaker CB6 OK.
Wire 708BB OK.
Wire 706C OK.
INTERIOR LIGHTS switch
S32 OK.
Faulty wire 706B.
Faulty relay K41.
Replace relay K41
(para 16-62).
e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT)