TM 9-2320-365-20-2
2-1118
START
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Visual inspection
1.
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
AC power connected (TM 9-2320-365-10).
Personnel Required
(2)
Go to step 8 of this fault.
This question helps
eliminate possible
problems and determines
where troubleshooting
continues.
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
POSSIBLE PROBLEMS
e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE
Lighting fixtures DS82
and DS83 OK.
Faulty fluorescent lamps.
Faulty wire 706B.
Faulty wire 1499J.
Faulty wire 3085AK.
Faulty lighting fixture.
Faulty wire 3085C.
Does lighting fixture
DS80 or DS81 operate?