TM 9-2320-365-20-3
7-27. 100 AMP REVERSE POLARITY RELAY REPLACEMENT (CONT)
(3) Lift terminal cover (4) on terminal lugs TL61 (5) and
TL47 (6).
(4) Remove nut (7), lockwasher (8), and terminal lugs TL61
(5) and TL47 (6) from 100 amp reverse polarity relay (9).
Discard lockwasher.
(5) Lift dust boot (10) on terminal lug TL44 (11).
(6) Remove nut (12), lockwasher (13), and terminal lug TL44
(11) from 100 amp reverse polarity relay (9). Discard
lockwasher.
NOTE
Perform step (7) on M1079.
(7) Remove terminal lug TL100 (14) from 100 amp reverse
polarity relay (9).
(8) Lift dust boot (15) on terminal lug TL80 (16).
(9) Remove nut (17), lockwasher (18), and terminal lug TL80
(16) from 100 amp reverse polarity relay (9). Discard
lockwasher.
(10) Lift terminal cover (19) on terminal lugs TL1 (20), TL37
(21), and TL36 (22).
(11) Remove nut (23), lockwasher (24), and terminal lugs TL1
(20), TL37 (21), and TL36 (22) from 100 amp reverse
polarity relay (9). Discard lockwasher.
7-134