TM 9-2320-365-20-3
(12) Remove six self-locking nuts (25), spring washers (26),
screws (27), and 100 amp reverse polarity relay (9) from
bracket (28). Discard spring washers and self-locking
nuts.
b. Installation.
(1) Position 100 amp reverse polarity relay (1) on bracket (2)
with six screws (3), spring washers (4), and self-locking
nuts (5).
(2) Tighten six screws (3) to 60-72 lb-in. (7-8 N·m).
(3) Position terminal lugs TL36 (6), TL37 (7), and TL1 (8) on
100 amp reverse polarity relay (1) with lockwasher (9)
and nut (10).
(4) Tighten nut (10) to 120-144 lb-in. (14-16 N·m).
(5) Position terminal cover (11) on terminal lugs TL36 (6),
TL37 (7), and TL1 (8).
(6) Install terminal lug TL80 (12) on 100 amp reverse
polarity relay (1) with lockwasher (13) and nut (14).
(7) Tighten nut (14) to 120-144 lb-in. (14-16 N·m).
(8) Position dust boot (15) on terminal lug TL80 (12).
7-135