TM 9-2320-365-20-3
7-77. POWER TAKE-OFF (PTO) CABLE ASSEMBLY REPLACEMENT (CONT)
(17) Position terminal lug TL76 (26) on screw (27) with self-
locking nut (28).
(18) Tighten self-locking nut (28) to 84-108 lb-in. (10-12 N·m).
(19) Connector P216 (29) to PTO pressure switch (30).
(20) Connect connector P217 (31) to PTO solenoid (32).
c. Follow-On Maintenance.
(1) Install kick panel (para 16-3).
(2) Connect batteries (para 7-48).
(3) Operate PTO and check for proper operation (TM 9-
2320-365-10).
(4) Operate 11K SRW and check for proper operation (TM
9-2320-365-10).
End of Task.
7-326