TM 9-2320-365-20-3
c. Load Sensing Valve Removal.
(1) Loosen jam nut (1) on cable clamp (2).
(2) Loosen screw (3) on cable clamp (2).
(3) Remove load sensing valve control cable (4) from cable
clamp (2).
NOTE
Tag air hoses and connection points prior
to disconnecting.
(4) Disconnect two air hoses (5) from tee fitting (6).
(5) Disconnect air hose (7) from 45-degree fitting (8).
(6) Remove two self-locking nuts (9), screws (10), washers
(11), and load sensing valve (12) from bracket (13).
Discard self-locking nuts.
Change 1
11-55