TM 9-2320-365-20-3
11-13. RELAY VALVE REPLACEMENT (CONT)
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to
skin and clothing. Keep away from
open fire and use in a well-ventilated
area. If adhesive, solvent, or sealing
compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury
to personnel.
(1) Apply antiseize compound to threads of plug (1), two
90-degree fittings (2), 90-degree fitting (3), two fittings
(4), and 45-degree fitting (5).
(2) Install plug (1) in relay valve (6).
(3) Install two 90-degree fittings (2) in relay valve (6).
(4) Install 90-degree fitting (3) in relay valve (6).
(5) Install two straight fittings (4) in relay valve (6).
(6) Install 45-degree fitting (5) in relay valve (6).
(7) Position relay valve (6) on panel (7) with two washers
(8), screws (9), and self-locking nuts (11).
(8) Tighten two self-locking nuts (11) to 14-18 lb-ft (20-24
N·m).
11-72
Change 1