TM 9-2320-365-20-3
(5) Remove two self-locking nuts (9), screws (11), washers
(12), and relay valve (13) from panel (14). Discard self-
locking nuts.
NOTE
Note orientation of fittings prior to
removal.
(6) Remove 45-degree fitting (8) from relay valve (13).
(7) Remove two fittings (4) from relay valve (13).
(8) Remove 90-degree fitting (6) from relay valve (13).
(9) Remove two 90-degree fittings (2) from relay valve (13).
(10) Remove plug (15) from relay valve (13).
Change 1
11-71