TM 9-2320-365-20-3
b. Installation
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to
skin and clothing. Keep away from
open fire and use in a well-ventilated
area. If adhesive, solvent, or sealing
compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury
to personnel.
(1) Apply antiseize compound to threads of fitting (1), run
tee fitting (2), branch tee fitting (3), 90-degree fitting (4),
reducer bushing (5), and air pressure transmitter (6).
(2) Install fitting (1) in two-way check valve (7).
(3) Install run tee fitting (2) in two-way check valve (7).
(4) Install branch tee fitting (3) in two-way check valve (7).
(5) Install 90-degree fitting (4) in branch tee fitting (3).
(6) Install reducer bushing (5) in tee fitting (3).
(7) Install low pressure transmitter (6) in reducer bushing
(5).
(8) Install two-way check valve (7) on cab (8) with washer
(9) and screw (10).
Change 1
11-141