TM 9-2320-365-20-4
b. Installation.
NOTE
All eight circuit breakers are installed the same
way. Circuit breaker CB8 shown.
Refer to Table 16-8. M1079 Circuit Breakers
and Wire Numbers for details.
Install plastic cable ties as required.
(1) Install circuit breaker CB8 (1) on 110/208 VAC POWER
DISTRIBUTION PANEL (2).
(2) Install wires 415 (3) and 400 (4) in circuit breaker CB8
(1).
(3) Tighten screw (5) on circuit breaker CB8 (1).
(4) Install
cover
(6)
on
110/208
VAC
POWER
DISTRIBUTION PANEL (7) with six screws (8).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-48).
(2) Connect AC power (TM 9-2320-365-10).
(3) Check for proper operation of affected circuit breaker
(TM 9-2320-365-10).
(4) Close LH and RH doors (TM 9-2320-365-10).
End of Task.
16-421