TM 9-2320-365-20-4
(2) Loosen three screws (4) in 200 amp circuit breaker (5).
NOTE
Tag wires and connection points prior to
disconnecting.
(3) Remove wires 500 (6), 501 (7), and 502 (8) from 200
amp circuit breaker (5).
(4) Remove two screws (9) from 200 amp circuit breaker (5).
(5) Remove three screws (10), 200 amp circuit breaker (5),
and three spacers (11) from 110/208 VAC POWER
DISTRIBUTION PANEL (3).
b. Installation.
(1) Install three spacers (1) and 200 amp circuit breaker (2)
in 110/208 VAC POWER DISTRIBUTION PANEL (3)
with three screws (4).
(2) Install two screws (5) in 200 amp circuit breaker (2).
(3) Install wires 502 (6), 501 (7), and 500 (8) in 200 amp
circuit breaker (2).
(4) Tighten three screws (9) in 200 amp circuit breaker (2).
16-423