TM 9-2320-365-20-4
16-66. M1079 110/208 VAC POWER DISTRIBUTION PANEL REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
15/20/30 and 50 amp AC circuit breakers removed
(para 16-64).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Dispenser, Pressure Sensitive Adhesive Tape (Item
21, Appendix D)
Materials/Parts (Cont)
Lockwasher (28) (van body serial numbers 001
through 190) (Item 77, Appendix G)
Lockwasher (16) (van bodies serial number 191
and higher) (Item 77, Appendix G)
Lockwasher (12) (Item 76, Appendix G)
Lockwasher (4) (Item 83, Appendix G)
Personnel Required
(2)
a. Removal
NOTE
Tag wires and connection points prior to
disconnecting.
Remove plastic cable ties as required.
(1) Loosen three screws (1) in 200 amp AC circuit breaker
(2).
(2) Remove wires 500 (3), 501 (4), and 502 (5) from 200
amp AC circuit breaker (2).
NOTE
Perform step (3) on van body serial numbers
001 through 190.
(3) Remove 28 screws (6), lockwashers (7), washers (8),
and cover (9) from 110/208 vac power entry panel (10).
Discard lockwashers.
16-425