TM 9-2320-365-20-4
16-68. M1079 110/208 VAC POWER IN/OUT CABLE REPLACEMENT (CONT)
(3) Install four washers (7), lockwashers (8), and nuts (9) on
screw (5) and three screws (6).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(4) Apply sealing compound on heads of screws (5 and 6)
and edges of 110/208 vac POWER OUT connector (2).
(5) Install dust cap (4) on 110/208 vac POWER OUT
connector (2).
16-460