TM 9-2320-365-20-5
20-55. 200 AMP ALTERNATOR KIT REMOVAL (CONT)
(91) Lift dust boot (142) on terminal lug TL35 (143).
(92) Remove self-locking nut (144), washer (145), and
terminal lug TL35 (143) from voltage regulator terminal
(146). Discard self-locking nut.
(93) Position washer (145) and self-locking nut (144) on
voltage regulator terminal (146).
(94) Lift dust boot (147) on terminal lug TL110 (148).
(95) Remove self-locking nut (149), washer (150), and
terminal lug TL110 (148) from voltage regulator terminal
(151). Discard self-locking nut.
(96) Position washer (150) and self-locking nut (149) on
voltage regulator terminal (151).
(97) Remove nut (152), washer (153), screw (154), and
washer (155) from alternator (141).
WARNING
200 amp alternator weighs approximately
70 lbs (32 kgs). The aid of an assistant is
required to remove 200 amp alternator.
Failure to comply may result in injury to
personnel.
NOTE
Step (98) requires the aid of an assistant.
(98) Remove nut (156), screw (157), washer (158), and
alternator (141) from alternator bracket (159).
20-346