TM 9-2320-365-20-5
20-57. 200 AMP VOLTAGE REGULATOR REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Cab raised (TM 9-2320-365-10).
Batteries disconnected (para 7-48).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Socket Set, Socket Wrench (Item 35, Appendix C)
Materials/Parts
Lockwasher (2) (Item 100, Appendix G)
Nut, Self-Locking (Item 130, Appendix G)
Nut, Self-Locking (Item 131, Appendix G)
Sealing Compound (Item 64, Appendix D)
a. Removal.
NOTE
Tag terminal lugs and connection points prior
to removal.
(1) Lift dust boot (1) on terminal lug TL110 (2).
(2) Remove self-locking nut (3), washer (4), and terminal lug
TL110 (2) from voltage regulator terminal (5). Discard
self-locking nut.
(3) Lift dust boot (6) on terminal lug TL35 (7).
(4) Remove self-locking nut (8), washer (9), and terminal lug
TL35 (7) from voltage regulator terminal (10). Discard
self-locking nut.
20-355