b. WTEC III TPSS Calibration.
NOTE
WTEC III TPSS requires calibration after
installation. Calibration is accomplished in
steps (1) through (4).
(1) Position master power switch to on and wait for neutral
(N) indication from WTEC III TPSS (TM 9-2320-365-10).
(2) Position master power switch to off (TM 9-2320-365-10).
(3) Perform steps (1) and (2) four more times.
(4) Position master power switch to on (TM 9-2320-365-10).
(5) Start engine (TM 9-2320-365-10).
(6) Check VOLTS gage for charge indication (TM 9-2320-
365-10).
NOTE
Transmission shifting may be rough until
WTEC III TPSS determines proper shift
points. Operating vehicle through each gear
range several times will allow WTEC III TPSS
to determine proper shift points.
(7) Test drive vehicle and check operation of vehicle through
all gear ranges several times (TM 9-2320-365-10).
(8) Shut down engine (TM 9-2320-365-10).
End of Task.