TM 9-2320-365-20-4
19-4. HYDRAULIC MANIFOLD REPLACEMENT/REPAIR (CONT)
(16) Install preformed packings (34, 35, and 36) and back-up
rings (37 and 38) on cartridge valve (39).
(17) Position cartridge valve (39) in hydraulic manifold (2).
(18) Tighten cartridge valve (39) to 40 lb-ft (54 N·m).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(19) Apply sealing compound to threads of plug (40).
(20) Position check valve (41), preformed packing (42),
spacer (43), setscrew (44), and plug (40) in CV1 orifice
(45).
(21) Tighten plug (40) to 21 lb-ft (28 N·m).
(22) Install two preformed packings (46) on plugs (47).
(23) Install two filters (48) and plugs (47) in hydraulic manifold
(2).
19-20.12
Change 1