KNOWN INFO
Is continuity present from
relay K19 terminals 30 to
87A?
TEST OPTIONS
REASON FOR QUESTION
If continuity is not present,
relay K19 is faulty.
YES
5.
e6. ENGINE CRANKS BUT DOES NOT START (CONT)
POSSIBLE PROBLEMS
Faulty relay K19.
Faulty dashboard cable
assembly.
Faulty engine control cable
assembly.
NO
Continuity Test or
STE/ICE-R Test #91
Replace relay K19 (para 7-9).
TEST OPTIONS
REASON FOR QUESTION
YES
6.
WARNING
Read WARNING
on following page.
KNOWN INFO
Voltage Test or
STE/ICE-R Test #89
This question eliminates
possible problems and
determines where
troubleshooting continues.
Go to step 8 of this fault.
NO
Is 24 VDC present from
relay K19 socket 30 on
PDP?
Fuel quantity OK.
Fuel/water separator primed.
Air cleaner hose or tube OK.
Start inhibit pushbutton switch
OK.
Fuel quantity OK.
Fuel/water separator primed.
Air cleaner hose or tube OK.
Start inhibit pushbutton switch
OK.
Relay K19 OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty engine control cable
assembly.
TM 9-2320-365-20-1
2-306 Change 1