CONTINUITY TEST
WARNING
VOLTAGE TEST
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
terminal lug TL29 on fuel solenoid.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, go to step 4 of
this fault.
(5) If continuity is present, fuel solenoid is
faulty, notify DS Maintenance.
(6) Lower cab (TM 9-2320-365-10).
Change 1 2-303
TM 9-2320-365-20-1
(1) Lower cab (TM 9-2320-365-10).
(2) Remove power distribution panel (PDP)
cover (para 16-2).
(3) Remove relay K19 from power distribution
panel (PDP).
(4) Set multimeter to volts DC.
(5) Connect positive (+) probe of multimeter
to relay K19 socket 86 on power
distribution panel (PDP).
(6) Connect negative (-) probe of multimeter to
ground
(7) Position master power switch to on
(TM 9-2320-365-10) and note reading on
multimeter.
(8) If 24 VDC is not present, go to step 5 of
this fault.
(9) If 24 VDC is present, replace start inhibit
pushbutton switch (para 7-19).
(10) Position master power switch to off
(TM 9- 2320-365-10).