TM 9-2320-365-20-3
(5) Remove two self-locking nuts (9), washers (10), screws
(11), washers (12) and anti-compounding relay valve
(13) from panel (14). Discard self-locking nuts.
(6) Remove plug (15) from anti-compounding relay valve
(13).
(7) Remove 90-degree fitting (8) from bushing (16).
(8) Remove bushing (16) from anti-compounding relay
valve (13).
(9) Remove 90-degree fitting (6) from anti-compounding
relay valve (13).
(10) Remove 90-degree fitting (4) from anti-compounding
relay valve (13).
(11) Remove two 90-degree fittings (2) from anti-
compounding relay valve (13).
11-63