TM 9-2320-365-20-3
11-11. ANTI-COMPOUNDING RELAY VALVE REPLACEMENT (CONT)
b. Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury to personnel.
(1) Apply antiseize compound to two 90-degree fittings (1),
90-degree fitting (2), 90-degree fitting (3), bushing (4),
90-degree fitting (5), and plug (6).
(2) Install two 90-degree fittings (1) in anti-compounding
relay valve (7).
(3) Install 90-degree fitting (2) in anti-compounding relay
valve (7).
(4) Install 90-degree fitting (3) in anti-compounding relay
valve (7).
(5) Install bushing (4) in anti-compounding relay valve (7).
(6) Install 90-degree fitting (5) in bushing (4).
(7) Install plug (6) in anti-compounding relay valve (7).
(8) Position anti-compounding relay valve (7) on panel (8)
with two washers (9), screws (10), washers (11), and
self-locking nuts (12).
(9) Tighten two self-locking nuts (12) to 14-18 lb-ft (20-24
N·m).
11-64