TM 9-2320-365-20-3
11-17. PARK CONTROL TWO-WAY CHECK VALVE REPLACEMENT (CONT)
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to
skin and clothing. Keep away from
open fire and use in a well-ventilated
area. If adhesive, solvent, or sealing
compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury
to personnel.
(5) Apply antiseize compound to threads of two air
pressure transmitters (5).
(6) Install two air pressure transmitters (5) in tee fittings (2).
(7) Position park control two-way check valve (4) on
bracket (6) with screw (7), washer (8), and self-locking
nut (9).
(8) Tighten self-locking nut (9) to 13-16 lb-ft (18-22 N·m).
11-88