TM 9-2320-365-20-3
11-23. SERVICE GLADHAND TWO-WAY CHECK VALVE REPLACEMENT (CONT)
NOTE
Note orientation of fittings prior to
removal.
(5) Remove 45-degree fitting (6) from service gladhand
two-way check valve (8).
(6) Remove 90-degree fitting (4) from service gladhand
two-way check valve (8).
(7) Remove branch tee fitting (2) from service gladhand
two-way check valve (8).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to
skin and clothing. Keep away from
open fire and use in a well-ventilated
area. If adhesive, solvent, or sealing
compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury
to personnel.
(1) Apply antiseize compound to threads of branch tee
fitting (1), 90-degree fitting (2), and 45-degree fitting (3).
(2) Install branch tee fitting (1) in service gladhand two-way
check valve (4).
(3) Install 90-degree fitting (2) in service gladhand two-way
check valve (4).
(4) Install 45-degree fitting (3) in service gladhand two-way
check valve (4).
11-124