TM 9-2320-365-20-4
16-71. M1079 12/24 VDC POWER ENTRY CONNECTOR REPLACEMENT (CONT)
NOTE
All wires on 12/24 vdc power entry connector
are removed the same way. One wire shown.
Tag wires and connection points prior to
disconnecting.
Refer to Table 16-9. M1079 Connector J173
Pin Letters and Wire Numbers for details.
(7) Remove wire (15) from 12/24 vdc power entry connector
J173 pin (16).
(8) Remove insulation sleeving (17) from wire (15).
(9) Perform steps (7) and (8) on remaining wires.
(10) Remove gasket (14) from 12/24 vdc power entry
connector J173 (7). Discard gasket.
Table 16-9. M1079 Connector J173 Pin Letters and Wire Numbers
PIN LETTER
A
B
C
D
E
F
G
H
WIRE NUMBER
2010
3086
2040
3086
UNUSED
2006
1507
1507
b. Installation.
NOTE
All wires on 12/24 vdc power entry connector
are installed the same way. One wire shown.
Refer to Table 16-9. M1079 Connector J173
Pin Letters and Wire Numbers for details.
(1) Position gasket (1) on 12/24 vdc power entry connector
J173 (2).
(2) Position insulation sleeving (3) on wire (4).
(3) Remove approximately 1/4 in. (0.6 cm) of insulation from
wire (4).
(4) Solder wire (4) to 12/24 vdc power entry connector J173
pin (5).
(5) Shrink insulation sleeving (3) on wire (4) and 12/24 vdc
power entry connector J173 pin (5).
16-476