TM 9-2320-365-20-4
16-72. M1079 12/24 VDC POWER ENTRY PANEL AND CONDUIT REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
12/24 vdc power entry connector removed (para
16-71).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Drill, Portable, Electric (Item 7, Appendix C)
Drill Set, Twist (Item 6, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
Materials/Parts
Sealing Compound (Item 67, Appendix D)
Rivet, Blind (22) (van body serial numbers 001
through 190) (Item 229, Appendix G)
Rivet, Blind (14) (van bodies serial number 191 and
higher) (Item 229, Appendix G)
Lockwasher (16) (Item 76, Appendix G)
a. Removal.
(1) Remove conduit nuts (1 and 2) from conduit connectors
(3 and 4).
(2) Remove conduit (5) and wires (6) from conduit connector
(3).
(3) Remove locknut (7) and conduit connector (3) from
12/24 vdc power entry panel (8).
(4) Remove sealing compound from edges of 12/24 vdc
power entry panel (8).
16-479