TM 9-2320-365-20-4
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(11) Apply sealing compound on edges of 12/24 vdc power
entry panel (17).
(12) Install conduit connector (18) in 12/24 vdc power entry
panel (17) with locknut (19).
(13) Install wires (8) and conduit (4) in conduit connector (18).
(14) Tighten nuts (2 and 3) on conduit connectors (5 and 18).
c. Follow-On Maintenance.
Install 12/24 vdc power entry connector (para 16-71).
End of Task.